Back to Top

1
Hi, Guest!
  • NASON
  • NASON - TRANSDUCER NT- 25

NASON - TRANSDUCER NT- 25

Update Terakhir
:
02 / 02 / 2022
Min. Pembelian
:
1 Unit

Harga

CALL
PERALATAN INSTRUMENT, ELECTRICAL, MECHANICAL, TOOLING, MEASUREMENT
( PERALATAN UKUR) SOLDERING & DESOLDERING

LARISSA TECHNOLOGY
Jl. Raya Alternatif Cibubur Km. 4, Cibubur 17435
Phone : 021 - 22813460 ; Fax : 021 - 84598635
No. WA : 0878 7304 1438 ; 0856 9498 2722
Email : [email protected]

www.larissatechnology.com

Detail NASON - TRANSDUCER NT- 25

NASON - TRANSDUCER NT- 25

- Features

- Totally digital proprietary design

- Innovative redundant sensing elements

- 24V digitaloutput for pressure or temp switch point

- Voltage and current outputs

- Custom pressure ranges and outputs available

- More standard pressure ranges, industry first

- Optional 4x over pressure is available up to 5, 000 PSI

- 0.25% accuracy

- ASIC technology, no zero/ span potentiometers

- All stainless steel welded housing

- IP-69K rated seal available ( high pressure wash down)

- Innovative low current consumption, ideal for custom wireless solutions

- Programmable systems available for OEM/ systems integrators for in-house configuring of outputs, ranges and set points to reduce inventory and lead times

- Calibration certificates available ( contact customer service) Specifications Performance Performance: @ 25° C ( 77° F) Accuracy: 0.25% BFSL ( includes: non-linearity, hysteresis and non-repeatability) Overange Protection : 2x Rated Pressure or optional 4x Pressure Range see ordering chart: - up to 6000 PSI ( 690 bar) ( optional higher ranges available) Burst Pressure: 5x or 20, 000 PSI, whichever is less Pressure Cycles: > 100 million Update Time: < = 1msec Digital Output Optional digital output for pressure or temp switch point ( not available on 4-20mA output units) Environmental Data Temperature Compensated Temperatures: -20° to 85° C ( -4 to 185° F) Operating Temperatures: -40° to 100° C ( -40 to 212° F) Storage: -40° to 125° C ( -40° to 250° F) Total Error Band ( TEB) : 0.9% Stability: 0.25% FS typical ( 1 year) Shock: 100g, 6 ms, 1/ 2 sine per EN 60068-2-27, EN 60068-2-29 Vibration: 12g peak, 10 to 2000 Hz per EN60068-2-6, EN60068-2-64 EMI/ RFI Protection Yes Rating Up: to IP-69K available ( high pressure wash down) Mechanical Configuration Pressure Connections See ordering chart Wetted Material: 17-4PH stainless steel ( for other materials consult factory) Electrical Connection: 9.4 Din, IP-69K 4 pin M12 Connector Case ( housing) : 304 stainless steel Electrical Data: Excitation 4.0-28 VDC, Typ ( must be at least 0.3V above full output voltage) ( 7.5 VDC min for 4-20mA) Output see ordering chart Output Load: 0-800 Ohms @ 10-28 VDC for current output 10K Ohms minimum for voltage outputs Current Consumption: 25mA max ( current output) , < 5mA ( voltage output) without digital output: , < 8mA with digital output Output Noise: < 2mV RMS Reverse Polarity Protection Yes Zero Offset: 1% CE Approval Yes. Shield must be attached to connector housing ( not tested with cable lengths over 30 meters) . Set Point for Either Pressure or Temperature For pressure, this is done by selecting a percentage of your transducer’ s full range and this will be the set point ( 40% of a 1000 PSI range will have the set point at 400 PSI) “ P40” . For temperature, simply select in degrees C where you want the set point to be ( selecting 40° C will be represented by " T40" in the part number) .

Tampilkan Lebih Banyak
Kontak Kami